ElectroGrid Smart Power Distribution System
ElectroGrid is an industrial-grade smart power grid management platform designed to model bulk 400kV HVAC electrical power generation, transmission line protection (ANSI 21/25), SF6 gas-insulated primary substations (GIS), 11kV vacuum circuit breaker (VCB) distribution, dynamic Static VAR Compensation (SVC ±15 MVAR), Advanced Metering Infrastructure (AMI), and automated Time-of-Use (ToU) electricity billing.
π οΈ Backend & Security Stack
- Core Runtime: Python 3.11+ & Flask Modular Blueprints
- Database ORM: SQLAlchemy (SQLite / PostgreSQL)
- Security & RBAC: Flask-Login, CSRF, AES-256 Audit Logs
- Telemetry Stream: 15-Min AMI Smart Meter Collector
β‘ Relay & Grid Standards
- Distance Protection: ANSI 21 (Sub-30ms Fault Isolation)
- Synchrocheck Relay: ANSI 25 Phase Angle Interlock
- Overcurrent / Earth Fault: ANSI 50/51 & 50N/51N
- Power Quality: Static VAR Compensator (SVC ±15 MVAR)
π High-Level 9-Stage Power Grid Architecture Flowchart
flowchart TD
subgraph S1_Generation ["Stage 1: Generation & 400kV Step-Up"]
GEN["β‘ Generation Plants (11kV / 22kV)"] --> GCB["π Generator Circuit Breaker (GCB)"]
GCB --> GSU["β‘ 400kV Step-Up Main Transformer"]
end
subgraph S2_Transmission ["Stage 2: 400kV HVAC Overhead Transmission"]
GSU --> LINE["ποΈ ACSR Quad-Bundle Overhead Lines"]
LINE --> DIST_RELAY["β‘ Distance Protection (ANSI 21)"]
end
subgraph S3_Substation ["Stage 3: Primary Substation (400kV -> 132kV)"]
DIST_RELAY --> GIS["π SF6 Gas-Insulated Switchgear"]
GIS --> XFORMER_500["β‘ 400kV / 132kV Step-Down Auto-Transformer"]
end
subgraph S4_Distribution ["Stage 4: Secondary Substation (132kV -> 11kV)"]
XFORMER_500 --> VCB["ποΈ Vacuum Circuit Breakers (VCB 31.5 kA)"]
VCB --> PROT["π‘οΈ Overcurrent Protection (ANSI 50/51)"]
end
subgraph S5_Control ["Stage 5: Smart Feeders & SCADA Billing"]
PROT --> SVC["β‘ Static VAR Compensator (SVC)"]
SVC --> RMU["π Ring Main Units (11kV -> 415V/230V)"]
RMU --> AMI["π‘ AMI Smart Meters & ToU Billing Engine"]
end
classDef send fill:#0f172a,stroke:#eab308,stroke-width:2px,color:#fff;
classDef line fill:#1e293b,stroke:#38bdf8,stroke-width:2px,color:#fff;
classDef prot fill:#312e81,stroke:#a78bfa,stroke-width:2px,color:#fff;
classDef recv fill:#064e3b,stroke:#10b981,stroke-width:2px,color:#fff;
class GEN,GCB,GSU send;
class LINE,DIST_RELAY,GIS line;
class XFORMER_500,VCB,PROT prot;
class SVC,RMU,AMI recv;
β‘ Technical Operating Envelope & Parameters
| Parameter Name | Operational Value & Rating |
|---|---|
| Bulk Transmission Voltage | 400.0 kV HVAC 3-Phase Synchronous (50.0 Hz) |
| Sub-Transmission Voltage | 132.0 kV AC |
| Distribution Feeder Voltage | 11.0 kV AC |
| Consumer Low Voltage | 415 V (3-Phase) / 230 V (1-Phase Residential) |
| SCADA Fault Isolation Speed | Sub-40ms High-Speed Trip Protection Trigger |
| Time-of-Use Tariff Rates | Peak: $0.38 / kWh | Off-Peak: $0.12 / kWh |